Vibration type level switches

CV-600 series
- Vibration type level switch that has a compact body and high sensitivity
Compact vibration level switch -
Ideal for detecting powder levels in small hoppers and small tanks.
Offers high reliability and high sensitivity (nominal specific gravity of 0.02) With a sensitivity selection switch (for 3 levels) to measure adhesive materials.
Features, keys |Line up |Usages, use examples |Standard specifications
Features, keys
- Easy to handle
No need for sensitivity adjustments and maintenance. - Optimum sensor mechanism for detection
Only the tip of the vibration rod is highly sensitive, and it does not mistakenly detect material stuck on the tank wall. - A high temperature type is also available
Sensors with a heat resistance of 150 degrees are also available. - Various functions are provided
Free-range power supply (20 to 250VAC/DC), fail-safe function, and CE marking.
Line-up
| Model name | CV-600 | CV-600-HT |
|---|---|---|
| Type | Compact, low priced general purpose switches | |
| Features | Idea for integrating into small tanks and equipment | |
| Major applications | Detects various powders, pellets, and chips. |
Detects various powders, pellets, and chips. Detects incinerated ash and resins. |
| Photograph | ![]() |
![]() |
Usages, use examples
For integrating into small tanks and equipment
- Detects levels of various powders, pellets, and chips.
Standard specifications
| Model name | CV-600 | CV-600-HT | |
|---|---|---|---|
| Amplifier | Maximum detection sensitivity (Nominal specific gravity of material to be measured) |
0.02 | |
| Input power source | 20 to 250 V AC/DC | ||
| Configuration of output contact points | 1C | ||
| Setting the output capacity | AC1250VA DC150W | ||
| Maximum open/close voltage | 250VAC | ||
| Maximum open/close current | 5A | ||
| Power consumption | 3VA or less | 3VA | |
| Allowable amplifier temperature | -20 to +60 degrees | ||
| Case | Protection class | IP67 | |
| Materials | Die-cast aluminum | ||
| Wiring hole | M16 X 1.5 | ||
| Detection probe |
Connection | R1 (Many optional flanges are available *1) | |
| Materials | SUS304 | ||
| Allowable temperature | -20 to +80 degrees | -20 to +150 degrees | |
| Allowable pressure *2 | 1.0MPa | ||
| Allowable load | 80N (offset load) | ||
*1: The flanges screw in to main housing.
*2: If the withstand pressure of the liquid contact areas is lower than this load value, the withstand pressure of the liquid contact area shall be applied.